Intelligent motor soft starter is produced by power electronics techn ology, microprocessor technology and modern control theorytechnology.New starter equipment. The product can efectively limit the stating voltage of the asynchronous motor when it isstarted, lt can be widely used in heavy-duty equipment such as fans, pumps, conveyors and compressors. it is a star/deltaconversion, auto-coupled step-down, magn etically controlled step-down, etc. The ideal replacement for start-up equipment.
● The customized number can be directly selected through a simple programming application load type
● Three groups of starting parameters are optional, which is convenient for one motor soft starter to start motor loads with different powers.
● The start detection motor feedback voltage realizes closed-loop control to ensure the successful start ofthe motor undeivarious working conditions and different loads.
● Three starting modes: voltage ramp starting mode can obtain the maximum output torque; The best starting current limitationof constant current soft starting mode, Wearing the soft start mode again can start the equipment with heavy load.
● Programmable delayed start mode, programmable interlock control.
● There is no phase sequence requirement for the input power supply.
● The starting time and stopping time can be digitally modified.
● It has multiple protection functions: over-current, three-phase current imbalance,overheating, phase loss, motor overload,etc
● The dynamic fault memory function is convenient for finding the cause of the fault.
● Field bus full dynamic control monitoring starter, easy to network.
● Main circuit working voltage: AC220V/690V (+10%-25%);
● Main circuit working current: 13A-1200A;
● Main circuit frequency: 50Hz/60Hz (±2%);
● Control loop power supply: AC220V + 15% (0.5A);
● Soft start rise time: 1-120S;
● Soft parking time: 0-100S;
● Impact time: 0.1-0.3S;
● Shock voltage: 50%-80%:
● Current limiting multiple: 1.5-5.0le:
● Initial voltage: 30% – 70% Ue;
● Cooling method: natural cooling;
● Communication method: RS485 serial communication.

a. LCD Display
b. Shift Keys
c. Program/Confirm key
d. Upward switching key
①Chrome Plated Copper Terminals
②Removable panel
③Operation Keys
④Stop/Reset key
⑤Local/Remote key
⑥Downward switching key
⑦Flame retardant housing
⑧Convenient terminal blocks

①Chrome Plated Copper Terminals
②Removable panel
③LCD display

| Power(KW) | External Dimension LxWxH(mm) |
| 15KW~37KW | 105*168.5*240 |
| 45KW~75KW | 135*184.5*282.5 |
| 90KW~110KW | 190*224.5*370.5 |
| 132KW~200KW | 225*226*393 |
| 220KW~400KW | 483*296*586 |
Main technical parameter
| Cooling Mode | Natural air cooling |
| Number Of Starts | 12/ 12 times/minute |
| Installation Method | Wall mounted or vertical cabinet |
| Vibration Resistance | Conform to lEC68-2-6: 1.5mm peak from 2 to 13Hz/lgn from 13 to 200Hz |
| Impact Resistance | Complies with lEc 68-2-27:15g,11ms |
| Maximum Environmental Pollution Leve | Class 3 according to lEC 947-4-2 |
| Maximum Relative Humidity | 93% non-condensing or dripping, according tolEC 68-2-3 |
| Maximum Operating Altitude | 2000 meters without derating (2000 meters or more, each additional 100meters,0.5% lower cunrent) |
| Run Position | Vertical position, within士10% |