The single phase variable transformer is a device that regulates voltage by continuously adjusting the turns ratio of an autotransformer. By sliding the regulator brushes along the polished surface of the coil, the output voltage can be smoothly adjusted from zero to the highest position.
Brand: Zhengxi or OEM&ODM
Model: TGDC3 Series
Waveform Distortion:No Additional Waveform Distortion
Working Frequency:50/60Hz
Insulation Resistance: Single Phase >5MΩ ,Three Phase >2MΩ
Withstand Voltage:2000V/1Min
Temperature Rise:<60°C
TDGC3 series variable auto transformer are characterized by waveform fidelity, compact size, light weight, high efficiency, easy operation, high reliability, and long time stable operation.
Widely used in voltage regulation, temperature control, light regulation, power control, metallurgical instruments, electromechanical manufacturing, light industry, scientific experiments, public utilities, household appliances and other fields, it is the ideal AC voltage regulator solution.
Working frequency: 50/60Hz
Efficiency: 95%.
Waveform distortion: no additional distortion
Temperature rise: <60°C Electrical strength: 2000V/min Insulation resistance: single-phase >5MΩ, three-phase >2MΩ
Maximum ambient temperature: +40℃, minimum ambient temperature: -5℃
Installation altitude not exceeding 1000 meters
Air relative humidity: average relative humidity of 90% in humid months, average air temperature of 25 ℃
Power supply voltage waveform: sinusoidal or sinusoidal-like waveforms
Installation environment: indoor, no gas, steam, chemical deposits, dust, dirt and other media that may affect the insulation performance of the voltage regulator. No violent vibration and bumps.

① Portable Handle
② Metal Case
③ Digital Display
④ Dial
⑤ Knob
⑥ Heat sink
⑦ Fuse
⑧ Switch

| Product model | Input voltage | Output voltage | (A) Maximum current | sizes(mm)xx LxWxH |
| TDGC3-500VA | 220V | 0-300Vtunable | 1.6 | 190*215*150 |
| TDGC3-1000VA | 3.3 | 225*250*180 | ||
| TDGC3-2000VA | 6.6 | 224*205*179 | ||
| TDGC3-3000VA | 10 | 235*285*230 | ||
| TDGC3-5000VA | 16.6 | 230*318*270 |
The formula for calculating the maximum power that can be loaded with the corresponding voltage value
Output loadable power (W)=output voltage (V) * maximum current
Note: The lower the output voltage regulation, the smaller the output power, the smaller the load power